Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 4.435
Filtrar
1.
Korean J Ophthalmol ; 2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38665112

RESUMO

Purpose: To assess efficacy, safety, and tolerability of the preservative-free fixed-dose combination of tafluprost 0.0015%/timolol 0.5% (PF tafluprost/timolol FC) in treatments-naïve patients with primary open-angle glaucoma (POAG). Methods: This was a retrospective, real-world clinical practice setting study that included 107 eyes of 107 subjects with POAG who had never been treated for glaucoma. All subjects were received PF tafluprost/timolol FC once daily. Intraocular pressure (IOP) levels were documented for each eye at the untreated baseline and up to six months after the initiation of medical treatment. All adverse events, including ocular and systemic adverse reactions, were recorded. Additionally, the reasons for medication discontinuations were thoroughly documented. Results: A total of 32 POAG patients with high-baseline IOP (> 21 mmHg) and 75 with normal-baseline IOP were included in the study. The subjects' baseline mean age was 62.4 ± 8.7 (range: 26 - 85 years); among them, 42 were women (39.3%). Mean IOP at baseline for all patients was 18.6 ± 4.3 mmHg. The mean IOP at six months was 12.6 ± 4.7 mmHg, representing a significant decrease compared to the baseline (-32%; P< 0.001). In POAG patients with high-baseline IOP, mean IOP was significantly lowered from 28.0 ± 5.7 mmHg at baseline to 18.0 ± 5.5 mmHg (-35%; P< 0.001); in patients with normal-baseline IOP, from 14.6 ± 3.4 mmHg to 10.3 ± 4.1 mmHg (-29%; P< 0.001). PF tafluprost/timolol FC was well tolerated and safe. After 6 months, 97.2% of all patients remained on therapy. Conclusions: In this real-world observational study, once-daily treatment with PF tafluprost/timolol FC demonstrated clinically relevant and statistically significant efficacy, as well as safety and good tolerability, in treatment-naive patients diagnosed with POAG.

2.
BMJ Open Ophthalmol ; 9(1)2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38626932

RESUMO

BACKGROUND/AIMS: This study aimed to investigate and compare the efficacy and safety of first-line and second-line selective laser trabeculoplasty (SLT) in Japanese patients with normal-tension glaucoma (NTG). METHODS: 100 patients with NTG were enrolled in this study. Patients were treated with SLT as a first-line or second-line treatment for NTG. Main outcome measures were intraocular pressure (IOP) reduction rate, outflow pressure improvement rate (ΔOP), success rate at 1 year and complications. Success was defined as ΔOP≥20% (criterion A) or an IOP reduction ≥20% (criterion B) without additional IOP-lowering eye-drops, repeat SLT or additional glaucoma surgeries. The incidence of transient IOP spike (>5 mm Hg from the pretreatment IOP), conjunctival hyperaemia, inflammation in the anterior chamber and visual impairment due to SLT were assessed. RESULTS: A total of 99 patients (99 eyes) were initially enrolled in this study, including 74 eyes assigned to the first-line SLT group and 25 eyes to the second-line SLT group. The mean IOP of 16.3±2.1 mm Hg before SLT decreased by 17.1%±9.5% to 13.4±1.9 mm Hg at 12 months after SLT in the first-line group (p<0.001), and the mean IOP of 15.4±1.5 mm Hg before SLT decreased by 12.7%±9.7% to 13.2±2.0 mm Hg at 12 months after SLT (p=0.005) in the second-line group. Both groups showed significant reductions in IOP. Higher pre-SLT IOP and thinner central corneal thickness were associated with greater IOP reduction. The success rate at 1 year was higher in the first-line compared with the second-line group, with lower pretreatment IOP and the use of IOP-lowering medication before SLT being associated with treatment failure. Most post-treatment complications were minor and transient. CONCLUSIONS: SLT may be an effective and safe treatment option for NTG, as either a first-line or second-line treatment. TRIAL REGISTRATION NUMBER: The study was registered in the UMIN-CTR (UMIN Test ID: UMIN R000044059).


Assuntos
Glaucoma , Lasers de Estado Sólido , Glaucoma de Baixa Tensão , Hipotensão Ocular , Trabeculectomia , Humanos , Trabeculectomia/efeitos adversos , Pressão Intraocular , Glaucoma de Baixa Tensão/cirurgia , Glaucoma/cirurgia , Hipotensão Ocular/cirurgia , Câmara Anterior , Lasers de Estado Sólido/uso terapêutico , Estudos de Coortes
3.
Turk J Ophthalmol ; 54(2): 83-89, 2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38645613

RESUMO

Objectives: To review the current literature related to the correlation between translaminar pressure difference (TLPD) and glaucoma. Materials and Methods: In this article, we conducted a literature review using MEDLINE via PubMed, Cochrane Eyes and Vision, and Google Scholar from 01/01/2010 to 31/12/2022. Search terms included "glaucoma", "intraocular pressure", "translaminar cribrosa pressure gradient/difference", "intracranial pressure", and "cerebrospinal fluid pressure". Of 471 results, 8 articles were selected for the meta-analysis. Results: Our meta-analysis demonstrated significantly higher intraocular pressure, lower cerebrospinal fluid pressure (CSFp), and greater TLPD in high-tension and normal-tension glaucoma groups compared to healthy groups. Conclusion: The differences in CSFp and TLPD between glaucoma and healthy people detected in current studies suggests a potential relationship between TLPD and glaucoma.


Assuntos
Pressão Intraocular , Doenças do Nervo Óptico , Humanos , Pressão Intraocular/fisiologia , Doenças do Nervo Óptico/diagnóstico , Doenças do Nervo Óptico/etiologia , Doenças do Nervo Óptico/fisiopatologia , Pressão do Líquido Cefalorraquidiano/fisiologia , Glaucoma/fisiopatologia , Tonometria Ocular , Glaucoma de Baixa Tensão/fisiopatologia , Glaucoma de Baixa Tensão/diagnóstico
4.
J Biomed Opt ; 29(3): 037003, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38560532

RESUMO

Significance: Glaucoma, a leading cause of global blindness, disproportionately affects low-income regions due to expensive diagnostic methods. Affordable intraocular pressure (IOP) measurement is crucial for early detection, especially in low- and middle-income countries. Aim: We developed a remote photonic IOP biomonitoring method by deep learning of the speckle patterns reflected from an eye sclera stimulated by a sound source. We aimed to achieve precise IOP measurements. Approach: IOP was artificially raised in 24 pig eyeballs, considered similar to human eyes, to apply our biomonitoring method. By deep learning of the speckle pattern videos, we analyzed the data for accurate IOP determination. Results: Our method demonstrated the possibility of high-precision IOP measurements. Deep learning effectively analyzed the speckle patterns, enabling accurate IOP determination, with the potential for global use. Conclusions: The novel, affordable, and accurate remote photonic IOP biomonitoring method for glaucoma diagnosis, tested on pig eyes, shows promising results. Leveraging deep learning and speckle pattern analysis, together with the development of a prototype for human eyes testing, could enhance diagnosis and management, particularly in resource-constrained settings worldwide.


Assuntos
Aprendizado Profundo , Glaucoma , Humanos , Animais , Suínos , Pressão Intraocular , Glaucoma/diagnóstico por imagem , Tonometria Ocular , Esclera
5.
Acta Ophthalmol ; 2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38572815

RESUMO

PURPOSE: To assess intra- (repeatability) and inter-observer (reproducibility) variability of laser speckle flowgraphy (LSFG) for retinal blood flow (RBF) measurement in 20 eyes of wild type (C57BL/6J) mice and effect of intravitreal Aflibercept on RBF in optic nerve head (ONH) region of 10 eyes of Ins2 (Akita) diabetic mice. METHODS: 'Mean blur rate (MBR)' was measured for all quadrants of tissue area (MT), vessel (MV) and total area (MA) of ONH region. Changes in MT were analysed at each timepoint. Repeatability was evaluated by measuring MBR variability without changing mouse head position, and reproducibility after resetting mouse head position by another operator. Coefficient of repeatability (CR) through Bland-Altman plot method coefficient of variation (COV) and Intraclass correlation coefficient (ICC) was calculated. Intravitreal Aflibercept (1 µg) was administered to Akita eyes and intraocular pressure (IOP) was measured using a tonometer at baseline, day 7, 14, 21 and 28 post-injection. Hurvich and Tsai's criterion was used. RESULTS: Coefficient of repeatability values of repeatability and reproducibility for all quadrants were within limits of agreement. Reliability was excellent (ICC 0.98-0.99) and reproducibility was moderate to excellent (ICC 0.64-0.96). There was a non-significant IOP increase in all Akita eyes at Day 28 (p > 0.05), and significant increase in MT in all quadrants at Day 21 and superior, inferior and temporal quadrants at Day 28 (p < 0.05). CONCLUSION: Laser speckle flowgraphy demonstrates excellent repeatability and moderate to excellent reproducibility in measuring RBF. Intravitreal Aflibercept injection results in a significant increase in MT up to 28 days post-injection without significant increase in IOP.

6.
Vet Ophthalmol ; 2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38575836

RESUMO

OBJECTIVE: The aim of this study was to document ophthalmic examination findings and provide reference values for ocular examinations and diagnostics in clinically normal Western tiger salamanders (Ambystoma mavortium) and to evaluate the mydriatic effect of a topical rocuronium bromide and identify any adverse effects. ANIMALS STUDIED: Sixteen Western tiger salamanders. PROCEDURE: A complete ophthalmic examination, including intraocular pressure via rebound tonometry [iCare® TonoVet (dog-setting) or iCare® TonoVet Plus (dog-setting)], and fluorescein and Rose Bengal stains, was performed. Ocular surface flora culture swabs were collected for microbiology in four salamanders. Rocuronium bromide (50 µL; 0.01 mg) was administered into each eye in three salamanders. Pupil size and constriction ability were evaluated up to 60 min following administration of rocuronium bromide. Distant visual examination and Doppler heart rate were used to monitor for potential adverse effects of rocuronium bromide. RESULTS: Observed ocular abnormalities included lipid keratopathy/keratitis (19%; 3/16), parasitic ophthalmitis (19%; 3/16), and cataracts (6.3%; 1/16). A significant difference was found between tonometry with iCare® TonoVet (11.5 ± 2.7 mmHg) versus TonoVet Plus (15.4 ± 3.7 mmHg) (p = .025). Fluorescein and Rose Bengal stains were negative in all salamanders. Ocular surface microbiology revealed a high incidence of contamination from environmental flora, with the most common isolate being unidentified as Gram-negative nonfermenters (75%; 3/4). No significant change in pupil size or constriction ability was observed with rocuronium bromide. CONCLUSION: This is the first study to document ocular examination findings and diagnostics in captive and wild urodeles and may serve as a reference for clinical assessment and future studies of the Western tiger salamander.

7.
Vet Ophthalmol ; 2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38576120

RESUMO

OBJECTIVE: To determine the accuracy of the Reichert® Tono-Vera® Vet rebound tonometer for canine intraocular pressure (IOP) measurement. ANIMALS STUDIED: Five normal canine ex vivo globes. PROCEDURES: The anterior chambers of five freshly enucleated normal canine eyes were cannulated and connected to a reservoir of Plasma-Lyte A and a manometer. Starting at a manometric IOP of 5 mmHg, the pressure was progressively increased to 80 mmHg by raising the reservoir. Triplicate IOP measurements were taken with the Tono-Vera® Vet from the central cornea using the dog setting and compared to the manometric pressure by linear regression analysis and Bland-Altman plots. RESULTS: There was a strong positive linear regression trend when comparing central corneal Tono-Vera® Vet IOPs to manometric pressures (r2 = .99) with solid agreement between the two methods. Compared to manometric IOPs, the Tono-Vera® Vet underestimated IOPs at higher pressures ≥70 mmHg. CONCLUSIONS: Measurement of IOPs from the central cornea with the Tono-Vera® Vet provided accurate results over a large range in normal canine globes compared to direct manometry. The mild to moderate underestimation of IOPs at high pressures was not considered clinically relevant.

8.
Artigo em Inglês | MEDLINE | ID: mdl-38578333

RESUMO

PURPOSE: This study aimed to evaluate changes in intraocular pressure following intravitreal dexamethasone implant injection, specifically in patients undergoing glaucoma filtration surgery. METHODS: The degree of increase in intraocular pressure was compared retrospectively among three groups. Group 1 comprised patients who underwent prior glaucoma filtration surgery (54 eyes). Group 2 included patients with or suspected glaucoma without such surgical history (20 eyes). Group 3 included patients without glaucoma (33 eyes). Pressure measurements were taken before the injection and at 1, 2, 3, and 6 months post-injection. A subgroup analysis was performed for pressure > 35 mmHg, > 30 mmHg, > 25 mmHg, and a difference > 10 mmHg between the peak and baseline pressure. RESULTS: Group 1 consistently displayed lower pressures compared with Group 2, with significant difference at both 1- and 6-month post-injections (15.09 mmHg vs. 18.10 mmHg, P = 0.042 and 13.91 mg vs. 17.25 mmHg, P = 0.040). The proportion of patients in Group 1 and Group 3 with pressures > 25 mmHg, > 30 mmHg, and a difference > 10 mmHg did not significantly differ (15.6% vs. 9.5%, P = 0.231; 3.1% vs. 2.3%, P = 0.867; and 17.1% vs. 7.1%, P = 0.231). Notably, Group 2 exhibited a significantly higher proportion within each category (> 25 mmHg, 24.0%; > 30 mmHg, 20.0%; > 10 mmHg difference, 28.0%). CONCLUSION: Intravitreal dexamethasone implant did not increase the risk of elevated intraocular pressure in patients with a history of glaucoma filtration surgery compared with patients with suspected glaucoma; the risk was similar to those without glaucoma.

9.
Case Rep Ophthalmol ; 15(1): 292-297, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38577525

RESUMO

Introduction: This report describes a case of elevated intraocular pressure following the use of 0.125% atropine eye drops in a child wearing orthokeratology lenses. Case Presentation: A 9-year-old boy presented to our clinic with myopia, and he had been wearing orthokeratology lenses overnight for 23 months. He was treated previously with a once-daily administration of topical 0.125% atropine eye drops to reduce myopic progression. Three days after treatment, his intraocular pressure was 36 mm Hg in the right eye and 32 mm Hg in the left eye. Two days after the discontinuation of atropine eye drops and overnight orthokeratology lenses, the intraocular pressure was 18/20 mm Hg in both eyes. Conclusion: Low-dose atropine eye drops can cause intraocular pressure elevation in patients wearing overnight orthokeratology lenses. Although it may resolve promptly, short-term follow-up with intraocular pressure checks may be necessary for the early diagnosis and treatment of this complication.

10.
Am J Ophthalmol ; 2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38579920

RESUMO

PURPOSE: To evaluate the association of mean intraocular pressure (IOP) and IOP variability (IOP fluctuation (SD of IOP) and the IOP range) with the rate of ganglion cell complex (GCC) layer thinning over time in patients with glaucoma. DESIGN: Prospective cohort study METHODS: :Participants with at least 4 visits and 2 years of follow-up of optical coherence tomography tests were included. A linear mixed-effect model was used to investigate the association of IOP parameters with the rates of GCC thinning. Subgroup analyses were conducted for eyes with early ((MD ≥-6 dB), and moderate to advanced stage (MD <-6 dB) at baseline. RESULTS: The cohort consisted of 369 eyes of 249 glaucoma patients (282 early glaucoma and 87 moderate to advanced glaucoma) with mean [SD] age of 68.2 (10.7) years over 5.1 years of follow-up. The mean rate of GCC change was -0.59 (95%CI, -0.67 to -0.52) µm per year. In multivariable models, faster annual rate of GCC thinning was associated with a higher IOP fluctuation (-0.17[ 95%CI,-0.23 to -0.11] µm per 1-mm Hg higher, P < 0.001) or higher IOP range (-0.07[95%CI, -0.09 to -0.05] µm per 1-mm Hg higher, P <0.001) after adjustment for mean IOP and other confounding factors. Similar results were found for early and moderate to advanced stages of glaucoma. CONCLUSIONS: IOP variability showed an independent association with macular change in patients with glaucoma regardless of severity at baseline, even after adjustment for mean IOP, supporting its potential value as a therapeutic target for clinical decision-making.

11.
Acad Radiol ; 2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38580519

RESUMO

RATIONALE AND OBJECTIVES: Primary open-angle glaucoma (POAG) is accompanied with gray matter (GM) changes across the brain. However, causal relationships of the GM changes have not been fully understood. Our aim was to investigate the causality of GM progressive changes in POAG using Granger causality (GC) analysis and structural MRI. MATERIALS AND METHODS: Structural MRI from 20 healthy controls and 30 POAG patients with elevated intraocular pressure (IOP) were collected. We performed voxel-wise GM volume comparisons between control and POAG groups, and between control and four POAG subgroups (categorized by IOP). Then, we sequenced the structural MRI data of all POAG patients and conducted both voxel-wise and region of interest (ROI)-wise GC analysis to investigate the causality of GM volume changes in POAG brain. RESULTS: Compared to healthy controls, reduced GM volumes across the brain were found, GM volume enlargements in the thalamus, caudate nucleus and cuneus were also observed in POAG brain (false discovery rate (FDR) corrected at q< 0.05). As IOP elevated, the reductions of GM volume were more severe in the cerebellum and frontal lobe. GC analysis revealed that the bilateral cerebellum, visual cortices, and the frontal regions served independently as primary hubs of the directional causal network, and projected causal effects to the parietal and temporal regions of the brain (FDR corrected at q<0.05). CONCLUSION: POAG exhibits progressive GM alterations across the brain, with oculomotor regions and visual cortices as independent primary hubs. The current results may deepen our understanding of neuropathology of POAG.

12.
Artigo em Inglês | MEDLINE | ID: mdl-38557355

RESUMO

Glaucoma is a blinding disease. Reduction of intraocular pressure (IOP) is the mainstay of treatment, but current drugs show side-effects or become progressively ineffective, highlighting the need for novel compounds. We have synthesized a family of perhydro-1,4-oxazepine derivatives of digoxin, the selective inhibitor of Na,K-ATPase. The cyclobutyl derivative (DcB) displays strong selectivity for the human a2 isoform and potently reduces IOP in rabbits. These observations appeared consistent with a hypothesis that in ciliary epithelium DcB inhibits the a2 isoform of Na,K-ATPase, which is expressed strongly in non-pigmented cells, reducing aqueous humor (AH) inflow. This paper extends assessment of efficacy and mechanism of action of DcB using an ocular hypertensive non-human primate model (OHT-NHP) (Macaca fascicularis). In OHT-NHP, DcB potently lowers IOP, in both acute (24 hour) and extended (7-10 day) settings, accompanied by increased aqueous humor flow rate (AFR). By contrast, ocular normotensive animals (ONT-NHP) are poorly responsive to DcB, if at all. The mechanism of action of DcB has been analyzed using isolated porcine ciliary epithelium and perfused enucleated eyes to study AH inflow and AH outflow facility, respectively. (1) DcB significantly stimulates AH inflow although prior addition of 8-Br-cAMP, which raises AH inflow, precludes additional effects of DcB. (2) DcB significantly increases AH outflow facility via the trabecular meshwork (TM). Taken together, the data indicates that the original hypothesis on the mechanism of action must be revised. In the OHT-NHP, and presumably other species, DcB lowers IOP by increasing AH outflow facility rather than by decreasing AH inflow.

13.
Vet Ophthalmol ; 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38563215

RESUMO

OBJECTIVE: To assess the accuracy of canine intraocular pressure (IOP) estimates from the eyeTelemed IOPvet indentation tonometer. ANIMALS STUDIED: Part 1 included 54 eyes from 28 Beagle dogs-23 ADAMTS10-mutants with open-angle glaucoma and 5 normals. Part 2 involved five normal canine ex vivo globes. PROCEDURE: Part 1 (in vivo) compared IOPvet estimates in normal and glaucomatous dogs to Reichert Tono-Vera® Vet rebound tonometry. The three IOPvet estimates were green (normal; <20 mmHg, according to the manufacturer), yellow (elevated; 20-30 mmHg), and red (high; >30 mmHg). In Part 2 (ex vivo), the pressure inside freshly enucleated normal canine eyes was progressively increased from 5 to 80 mmHg and compared to IOPvet estimates. Descriptive statistics compared IOPvet estimates to rebound tonometry and direct manometry, with the threshold from normal to glaucoma set at 30 mmHg. RESULTS: In Part 1 (in vivo), normal pressures (≤30 mmHg) were mainly identified correctly as green or yellow-110 of 111 estimates, corresponding to a specificity of 99%. Only 16 of 125 affected estimates were correctly displayed in the >30-mmHg range; the remaining 109 showed ≤30 mmHg, corresponding to a sensitivity of 13%. In Part 2 (ex vivo), all normal pressures were correctly estimated with green, but 64 of 88 manometric IOPs >30 mmHg were falsely estimated as 20-30 mmHg. CONCLUSIONS: The IOPvet is inaccurate in estimating canine IOP with a low sensitivity at identifying dogs with IOP > 30 mmHg. Canine-specific instrument revision is required to correctly identify elevated (yellow = 20-30 mmHg) and high (red >30 mmHg) IOPs.

14.
Int Ophthalmol ; 44(1): 200, 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38662305

RESUMO

PURPOSE: To analyse real-world outcomes in Asian eyes of iStent inject, a second-generation trabecular micro-bypass stent, combined with phacoemulsification. METHODS: This is a multi-centre, observational study of glaucomatous Asian eyes that have undergone iStent inject implantation combined with cataract surgery. Patient data were extracted from the Fight Glaucoma Blindness! Registry. Outcome measures included those of IOP reduction, glaucoma medication reduction, and adverse events including the need for secondary surgery. RESULTS: 123 eyes of 86 patients with a mean age of 68.4 ± 9.3 years underwent iStent inject implantation with phacoemulsification. At baseline, the mean ± SD preoperative intraocular pressure (IOP) was 16.0 ± 4.4 mmHg, and the mean preoperative number of topical glaucoma medications was 1.9 ± 1.4. At 12 months 30.8% of eyes demonstrated a reduction in IOP greater than 20%, the mean IOP reduction was 12.5% with an additional reduction of 0.7 glaucoma medications. 40% of eyes were using no medications at 12 months compared to 16.3% preoperatively. 8.2% of eyes required a subsequent procedure within the 12-month follow-up window. CONCLUSION: iStent inject implantation combined with phacoemulsification in Asian eyes showed a reduction of IOP and glaucoma medication use in a real-world clinical setting. The safety profile of the device is good with minimal adverse outcomes, however, a subset of patients required secondary procedures within the 12 month follow up.


Assuntos
Pressão Intraocular , Sistema de Registros , Humanos , Masculino , Feminino , Idoso , Pressão Intraocular/fisiologia , Pessoa de Meia-Idade , Implantes para Drenagem de Glaucoma , Austrália/epidemiologia , Acuidade Visual , Resultado do Tratamento , Glaucoma/cirurgia , Glaucoma/fisiopatologia , Glaucoma/etnologia , Glaucoma/complicações , Facoemulsificação/métodos , Seguimentos , Idoso de 80 Anos ou mais , Povo Asiático/etnologia , Catarata/complicações , Estudos Retrospectivos
15.
J Equine Vet Sci ; 136: 105074, 2024 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-38648909

RESUMO

The aim of this study was to evaluate the intraocular pressure (IOP) measurements obtained from first, second, and third probe-cornea touch (PCT) and compare them with the average of six PCTs using two rebound tonometers in horses. This study enrolled a total of thirty-eight stallions, comprising of 24 Arabian horses and 14 cross-breeds (with an average age of 8 ± 3 years). The IOP measurements of first, second, and third, as well as the average of six PCTs were obtained using either Tonovet (TV) or Tonovet Plus (TV+) rebound tonometers. The mean differences (95% limits of agreement) between the average of six PCTs and the first, second, and third PCTs were 0.1 (-4.8 to 5), 0.2 (-4.8 to 4.5), and 0.2 (-3.6 to 4.0) mmHg with TV, respectively. With TV+, the differences were 0.3 (-6.6 to 7.2), 1.1 (-8.6 to 10.8), and -0.2 (-3.6 to 4.0) mmHg, respectively. Compared to the average of six PCTs, only 89.5%, 92.1%, and 97.4% of IOP measurements obtained from TV and 78.9%, 73.3%, and 65.8% of IOP measurements obtained from TV+ were within 4 mmHg of the average of six PCTs for first, second, and third PCTs, respectively. In conclusion, the measurement of IOP in the first PCT achieved best agreement with the IOP measurement of six average PCTs. Therefore, the first PCT could be considered as an alternative option for measuring IOP in horses when obtaining an average of six PCTs is not feasible.

16.
Artigo em Inglês | MEDLINE | ID: mdl-38651323

RESUMO

Flexible bioelectronic devices that can perform real-time and accurate intraocular pressure (IOP) monitoring in both clinical and home settings hold significant implications for the diagnosis and treatment of glaucoma, yet they face challenges due to the open physiological environment of the ocular. Herein, we develop an intelligent wireless measuring contact lens (WMCL) incorporating a dual inductor-capacitor-resistor (LCR) resonant system to achieve temperature self-compensation for quantitative IOP monitoring in different application environments. The WMCL utilizes a compact circuitry design, which enables the integration of low-frequency and high-frequency resonators within a single layer of a sensing circuit without causing visual impairment. Mechanically guided microscale 3D encapsulation strategy combined with flexible circuit printing techniques achieves the surface-adaptive fabrication of the WMCL. The specific design of frequency separation imparts distinct temperature response characteristics to the dual resonators, and the linear combination of the dual resonators can eliminate the impact of temperature variations on measurement accuracy. The WMCL demonstrates outstanding sensitivity and linearity in monitoring the IOP of porcine eyes in vitro while maintaining satisfactory measurement accuracy even with internal temperature variations exceeding 10 °C. Overcoming the impact of temperature variations on IOP monitoring from the system level, the WMCL showcases immense potential as the next generation of all-weather IOP monitoring devices.

17.
Int J Mol Sci ; 25(7)2024 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-38612500

RESUMO

Increased intraocular pressure (IOP) is the most important risk factor for glaucoma. The role of IOP fluctuation, independently from elevated IOP, has not yet been confirmed in glaucoma. We investigated the effects of IOP fluctuation itself on retinal neurodegeneration. Male rats were treated with IOP-lowering eyedrops (brinzolamide and latanoprost) on Mondays and Thursdays (in the irregular instillation group) or daily (in the regular instillation group), and saline was administered daily in the normal control group for 8 weeks. The IOP standard deviation was higher in the irregular instillation group than the regular instillation group or the control group. The degree of oxidative stress, which was analyzed by labeling superoxide, oxidative DNA damage, and nitrotyrosine, was increased in the irregular instillation group. Macroglial activation, expressed by glial fibrillary acidic protein in the optic nerve head and retina, was observed with the irregular instillation of IOP-lowering eyedrops. Microglial activation, as indicated by Iba-1, and the expression of TNF-α did not show a significant difference between the irregular instillation and control groups. Expression of cleaved caspase-3 was upregulated and the number of retinal ganglion cells (RGCs) was decreased in the irregular instillation group. Our findings indicate that IOP fluctuations could be induced by irregular instillation of IOP-lowering eyedrops and this could lead to the degeneration of RGCs, probably through increased oxidative stress and macrogliosis.


Assuntos
Glaucoma , Pressão Intraocular , Masculino , Animais , Ratos , Retina , Glaucoma/tratamento farmacológico , Células Ganglionares da Retina , Soluções Oftálmicas
18.
Rom J Ophthalmol ; 68(1): 37-44, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38617725

RESUMO

Aim: To assess the incidence, risk factors, and treatment outcomes in intravitreal triamcinolone acetonide injection (IVTA) induced intraocular pressure rise and to compare IOP rise in 1-mg and 2-mg IVTA. Materials and methods: Prospective observational study conducted in all eyes receiving IVTA. Any pre-existing glaucoma and patients who received IVTA or dexamethasone implant in the last 6 months were excluded. Results: 9 between 61-70 years of age developed an IOP spike. The mean and standard deviation of age in years was 61.95 ± 8.70. Maximum eyes had ME due to Diabetic Retinopathy (53.3%). All cases of uveitic ME were reported to have an IOP spike. 2 out of 3 high myopic eyes and 1 eye with thyroid abnormality had an IOP spike. High IOP was found in 13 eyes, with more than 25 mm Hg rise in 4 eyes and more than 5 mm Hg rise from baseline IOP in 9 eyes. The mean and standard deviation of time taken for IOP raise (in days) was 46.39 ± 37.68. A total of 38 eyes received 1 mg of IVTA and the rest 22 received 2 mg of IVTA. 23.7% of 1 mg eyes experienced an IOP rise while it was 18.2% in eyes with 2 mg IVTA. The injection was repeated in 12 eyes and 41.7% developed an IOP spike among them. The independent "t" test results showed that there was a significant difference in the mean of IOP (Pre-injection) concerning the IOP rise (P=0.007*). 1 eye had IVTA crystals in the anterior chamber with raised IOP of 30 mm Hg. 1 out of 13 eyes with raised IOP needed 2 AGMs, the other 12 eyes responded well to 1 AGM. Discussion: IVTA is widely used in refractory cases of ME and steroid-induced glaucoma is the most common side effect of IVTA. To the best of our knowledge, there is a lack of literature on prospective studies on IVTA-associated risk factors, patterns of IOP elevation, and treatment outcomes. The pre-injection mean ± SD baseline IOP for uneventful eyes was 12.87±2.65 and the pre-injection mean IOP for eyes with IOP event was 15.23±2.89 (P=0.007*). Conclusion: We proposed that TA is an independent risk factor for post-intravitreal injection IOP spike. IVTA causes a maximum IOP spike at 1 to 2 months and has a protracted course that responds to anti-glaucoma medications. High baseline IOP, a repeated dose of IVTA, the presence of TA crystals in the anterior chamber, and high myopia were associated with significant IOP elevation. Abbreviations: ACD = Anterior chamber depth, AS = Anterior segment, AGM = Anti-glaucoma medications, ARMD = Age-related macular degeneration, BCVA = Best-corrected visual acuity, BRVO = Branch retinal vein occlusion, CCT = Central corneal thickness, CRVO = Central retinal vein occlusion, CME = Cystoid macular edema, CNVM = Choroidal neovascularization membrane, CSME = Clinically significant macular edema, DR = Diabetic retinopathy, ERM = Epiretinal membrane, IOP = Intraocular pressure, IGS = Irvine-Grass syndrome, GAGs = Glycosaminoglycans, IVTA = Intravitreal triamcinolone acetonide injection, ME = Macular edema, NVG = Neovascular glaucoma, OHT = Ocular hypertension, PDS = Pigment dispersion syndrome, PACG = Primary closed angle glaucoma, POAG = Primary open-angle glaucoma, PXF = Pseudoexfoliation, VA = Visual acuity, VEGF = Vascular endothelial growth factors, VH = Vonherick's grading, SD = Standard deviation, TA = Triamcinolone acetonide, TIGR = Trabecular meshwork inducible glucocorticoid response.


Assuntos
Retinopatia Diabética , Glaucoma de Ângulo Aberto , Glaucoma , Degeneração Macular , Edema Macular , Miopia , Oclusão da Veia Retiniana , Humanos , Agentes Antiglaucoma , Pressão Intraocular , Edema Macular/diagnóstico , Edema Macular/tratamento farmacológico , Estudos Prospectivos , Triancinolona Acetonida , Pessoa de Meia-Idade , Idoso
19.
Int Ophthalmol ; 44(1): 182, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38625418

RESUMO

BACKGROUND/AIMS: This work aimed to investigate changes in optic nerve head (ONH) morphometry based on Bruch membrane opening in children with extensive nocturnal intraocular pressure (IOP) elevations. METHODS: The course of Bruch membrane opening-based optic nerve head (ONH) morphometry was analysed in thirty-two patients younger than 18 years with evaluable SD-OCT examinations of the ONH and nocturnal posture-dependent IOP elevation above 25 mmHg. Longitudinal changes in neuroretinal rim tissue, as measured by Bruch Membrane opening minimum rim width (BMO-MRW) and peripapillary retinal nerve fiber layer (RNFL) thickness, were assessed. RESULTS: One year after the 24 h IOP measurement, global BMO-MRW (- 1.61 ± 16.8 µm, n.s.; p = 0.611) and RNFL (+ 0.64 ± 3.17 µm; n.s.; p = 0.292) measurements were not significantly different from the baseline. No significant BMO-MRW reduction (- 3.91 ± 24.3 µm; n.s. p = 0.458) or deviation in RNFL thickness (+ 1.10 ± 3.52 µm) was observed at the four-year follow-up. Absolute IOP values measured in the supine position did not correlate with changes in global BMO-MRW or RNFL thickness. CONCLUSION: Posture-dependent IOP elevations do not seem to influence retinal nerve fibre layer thickness or Bruch membrane opening-based morphometric data in childhood.


Assuntos
Oftalmopatias , Disco Óptico , Criança , Humanos , Pressão Intraocular , Tonometria Ocular , Retina , Postura
20.
Front Med (Lausanne) ; 11: 1365259, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38633303

RESUMO

Purpose: SCUBA diving exposes participants to a unique hyperbaric environment, but few studies have examined the effects of such an environment on intraocular pressure (IOP) and glaucoma. This systematic review aims to consolidate recent literature findings regarding the impact of increased atmospheric pressure on IOP and glaucoma. Methods: Three online databases were searched to identify publications encompassing the subjects of diving or increased atmospheric pressure in conjunction with IOP or glaucoma. Three reviewers independently screened the publications and identified eligible articles. Relevant data was extracted from each article. The heterogeneity of the data precluded the conduct of a meta-analysis. Results: Nine studies met the inclusion criteria. Six experimental studies employed hyperbaric chambers to measure IOP under simulated diving conditions. Among these, IOP exhibited a reduction with increased atmospheric pressures in four studies, while the findings of two studies were inconclusive. One study measured IOP pre- and post-dive and another measured IOP with and without a diving mask. Post-dive, a decrease in IOP was observed, and a statistically significant reduction was noted when subjects wore a diving mask. A retrospective study examining the incidence of acute angle closure glaucoma attack found no association with weather or atmospheric pressure. Conclusion: The majority of studies found IOP to decrease with increased atmospheric pressure and after diving. The mechanisms underlying this reduction remain incompletely understood, with potential contributors including changes in ocular blood flow, sympathetic responses, and increased oxygenation. Hyperbaric chambers may have potential in future glaucoma treatments, but more studies are required to draw reliable conclusions regarding the safety of diving for glaucoma patients.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...